Products | Application Field | Collaborators | Careers | Location | Clientele | Useful Info
Assembly Line Automation and SPMs
Leak Testing Machines
Sensors & Instruments
Air Leak Testers & Flow Meters
Laminar & Massflow meters
Hydrogen Leak Testers
Helium Leak Testers
Education Labs
Civil Engineering
Air Leak Testers & Flow Meters
Air Leak Testers
Masterless Leak Tester – FL 600 Series
  • Shortened Testing Time – Advanced Data Management allows reduction of Testing
    Time
  • Detection Accuracy – Possible to conduct high S/N Testing, eliminates temperature influences and test various work parts
  • Masterless – Eliminates Master Management Processes
  • Improving outside factors – Problems involved with testing systems are assigned a numerical valve consequency; problems are solved with effective counter measures
    Corresponds to Multiple work parts – Flexibility allows multiple work parts adaptability
  • Extensive Maintenance Functions – Auigomatic self check functions for internal varies and various sensors. Flow Master and Calibrator allow volume testing and sensitivity verification
  • Model : V, UL, L, M, H
  • Pressure Range :
    • V for Vacuum type: -5.0 ~ -90.0 kPa
    • UL, L, M, H for Pressure type: 5.0 - 990 kPa
 
Master-Less Leak Tester FL-610 series
(Patented)
  • Master Management Not Needed
  • High Accuracy and Short Measurement Time
  • Equipped with USB Ports
  • A Variety of Parts Covered
  • Large-sized Graphic Color Display
 
Multi-purpose Leak Tester FL-601 Series

Revolutionary differential pressure type Masterless Air Leak Tester takes our FL-600 Series one step further into future. This space saving instrument will lead to gradual reduction in leading costs, and the detection time has become even shorter.

  • Model : V, UL, L, M, H, H1
  • Pressure Range :
    • V for Vacuum type: -5.0 ~ -90.0 kPa
    • UL, L, M, H, H1 for Pressure type: 5kPa ~ 2.00 MPa
 
Leak tester with Temperature Compensation
FL 612 Series
  • Increase productivity
  • Reduce equipment costs
  • Compatible with high temperature work
  • Increase precision
 
Corresponds to Work Volume Leak Testers
FL-2600, 2700, 3600, 3700, 3800 Series
  • FL-3600/3700 Series with turbo function loaded
    FL-2600/2700 Series without turbo function loaded
  • Turbo Function Loaded - Without Master work piece rapid stabilizing function
  • 10 Channel Group Setting – 10 kinds of different conditions can be set
  • Sensor Protect Circuit – Built-in circuitry to prevent moisture and oil from the work entering sensor
  • Data Management – Powerful line of Leak Tester designed to the product volume and to perform high accurate leak testing
  • Model : V, UL, L, M, H, H1, H2
  • Pressure Range :
    • Vacuum type : -7.0 ~ -90.0 kPa
    • Pressure type: 5 kPa ~ 3.5 MPa
  • Work Volume : 1ml to 50 Litres
 
Compact Air Leak Testers
FL-273, 283, 284, 294 Series
  • Compact Body, Collected substantial functions, High durability & Easy Operation
  • Model : V, L, M, H
  • Pressure Range
    • : V for Vacuum type : -20 ~ -90 kPa
    • L,M,H for Pressure type: 10 kPa ~ 990 kPa
 
Compact Air Leak Testers
FL-286, 296 Series
  • Compact Body, Collected substantial functions, High durability & Easy Operation
  • Model : UL, L, H
  • Model and Pressure Range:
  • UL type : -10 ~ 10 kPa
  • L type : -100 ~200 kPa
  • H type : -100 ~990 kPa
 
Flow Meters
Separate Leak Tester - LPU Series

The LPU Series our separate Air Leak Tester Measurement Units intended to be embedded in automated equipment. Complete Air Leak Tester can be created by pairing a separate Leak Tester with an option display unit (MI-170, DG-960)

  • Model & Pressure Ranges
  • V for Vacuum: -6.0 ~ -100 kPa
  • L for Low Pressure: 5.0 ~ 200 kPa
  • H for High Pressure : 100 ~ 900 kPa
 
 
Flow Tester FM-1060 Series

FM-1060 Series is a Flow Tester which houses a thermal flowmeter. It reduces measurement time by using scan function

  • Model: V, UL, L, M
  • Pressure Range:
    • V for Vacuum type : -5 ~ 50kPa
    • UL, L, M for Pressure type: 100 ~ 500 kPa
  • Flow Rate:
    • 500M: 50 ~ 500 ml
    • 2L: 0.2 ~ 2 l / min.
    • 5L: 0.5 ~ 5 l / min.
    • 20L: 2 ~ 20 l / min.
    • 50L: 5 ~ 50 l / min.
 
Multipurpose Flow Tester
  • Self-Check Simplified Using the Maintenance Keys
  • Corresponds Quickly to Environmental change and
    work exchange
  • Large LCD Display for Convenient Settings and
    Indications
  • Data Analysis, Estimate and Maintenance
Laminar flow element with indicator
  • Flow rate measurement is realized with pressure
    and temperature compensation
  • It also displays Gauge Pressure,
    differential pressure and Temperature.
  • High resistant to contamination
    (~70kPaG ~300kPaG)
  • The Laminar Element has a fast response and
    excellent linearity.
 
Flow Unit FU Series
  • Integral Structure makes it inexpensive and easy to operate flow measurement
  • Display separate unit makes it easy to integrate into equipment enable to employ pipeline as minimum structure
  • Applied Pressure Range: -20 ~ 100 kPa
  • Power Source: DC ± 15 V within 0.05 A
  • Model: 10M ~ 5L
  • Test Range: 1 ~ 10 (ml/min.) to 0.5 ~ 5 (l/min.)
 
Laminar FLF Series
  • Speed Response Characteristics
  • Small Pressure Loss
  • Tough for Impurity
  • Applied Pressure Range –20 ~ 100 kPa
  • Model: 20CM ~ 20 LM
  • Flow Range: 2 ~ 20 (ml/min.) to 2 ~ 20 (l/min.)
 
 
Flow Master FFM-100 Series

Detachable – The attachment and detachment to a main body can be performed, without removing measurement piping, by equipping the measurement circuit with coupling before hand

  • Routine – During the routine measurement, a plug is attached in coupling and the measurement course is changed in to a sealing state
  • Measurement – In case it measures, measurement becomes possible by substituting a plug into the main body
  • Pressure Range:
    • Pressure type: 10 kPa ~ 800 kPa
    • Vacuum type : 10 kPa ~ -80 kPa
    • Flow Rate : 0.1 ml/min. ~ 10.0 ml/min ±5%
    • Connection Caliber Coupling: R- ¼ (coupling)
 
Pressurization & Exhaust Bypass Unit

By using a pressurizations & exhaust by-pass unit you can reduce the test time of a large volume work and obtain stable measurement results

  • Model: EBU CBU
  • Power Supply Voltage: DC 24 V
  • Consumption Current: 0.1 A
 
Exhaust Bypass Unit

Allows pressurized air to exit from the work during the exhaust phase without passing through to the tester

  • Model: FE-20
  • Power Supply Voltage: AC-100V ±10%
  • Power Consumption: 1.8W
 
Calibrator

This is used in conjunction with a differential pressure Air Leak Tester, it can be used to check the sensitivity of an air leak tester or measure the volume of work by examining the developed differential pressure.

 
ˆ Top
© 2007 Syscon Instruments Pvt. Ltd.
Powered by Business Online, Bangalore