Pressure High Range Type
  • Strain Gauge Wheat-stone Bridge Principle
  • From 100 Kg./Cm.Sq. to 2000 Kg./Cm.Sq. in various
    Ranges & Models
  • Safe Over Load: 125% of Rated Capacity
  • Maximum Over Load : 150% of Rated Capacity
  • Fatigue Rating : 10 E6 Full Cycles
  • Excitation Maximum: 10 VDC
  • Sensitivity: 1 mV/V [Nominal]
  • Temperature Range: +10 Deg. C. to +50 Deg. C.
 
Pressure Low Range Type
  • Strain Gauge Wheat-stone Bridge Principle
  • From Vacuum to 5 Kg./Cm.Sq.in various Ranges & Models
  • Safe Over Load: 125% of Rated Capacity
  • Maximum Over Load : 150% of Rated Capacity
  • Fatigue Rating : 10 E6 Full Cycles
  • Excitation Maximum: 10 VDC
  • Sensitivity: 1 mV/V [Nominal]
  • Temperature Range: +10 Deg. C. to +50 Deg. C.
 
. Pressure Medium Range Type
  • Strain Gauge Wheat-stone Bridge Principle
  • From 5 Kg./Cm.Sq. to 100 Kg./Cm.Sq. in various Ranges & Models
  • Safe Over Load: 125% of Rated Capacity
  • Maximum Over Load : 150% of Rated Capacity
  • Fatigue Rating : 10 E6 Full Cycles
  • Excitation Maximum: 10 VDC
  • Sensitivity: 1 mV/V [Nominal]
  • Temperature Range: +10 Deg. C. to +50 Deg. C.
 
. Pressure Indicator
  • 3 ½ OR 4 ½ digit LED / LCD Displays
  • Single Channel OR Multi-Channel
  • Various Options:
    • Set Points & Outputs
    • Voltage & Current Outputs
    • Peak hold / Reset Facility
    • RS 232 / Centronics Outputs
    • Remote Inputs etc.
  • Calibration in Required Units
  • In Various Cabinet Sizes
  • +10 Deg.C. to +45 Deg.C.
  • 230 Volts AC, 50 Hz., Single Phase Operated
 
Signal Conditioner
  • Single Channel OR Multi-Channel
  • Voltage OR Current Outputs
  • In Various Cabinet Sizes
  • +10 Deg.C. to +45 Deg.C.
  • 230 Volts AC, 50 Hz., Single Phase Operated
 