Compression Column
Type |
- Strain Gauge Wheat-stone Bridge Principle
- From 100 Kg. to 500 Tonne in various Ranges
& Models
- Safe Over Load: 125% of Rated
Capacity
- Maximum Over Load : 150%
of Rated Capacity
- Fatigue Rating : 10 E6 Full
Cycles
- Excitation Maximum: 10 VDC
- Sensitivity: 1 mV/V [Nominal]
- Temperature Range: +10 Deg.
C. to +50 Deg. C.
|
|
| |
|
| Universal
Column Type |
- Strain Gauge Wheat-stone Bridge Principle
- From 500 Kg. to 100 Tonne in various Ranges
&
- Models with Hooks for Tension Application
& Loading Button for Compression Application
- Safe Over Load: 125% of Rated
Capacity
- Maximum Over Load : 150%
of Rated Capacity
- Fatigue Rating : 10 E6 Full
Cycles
- Excitation Maximum: 10 VDC
- Sensitivity: 1 mV/V [Nominal]
- Temperature Range: +10 Deg.
C. to +50 Deg. C.
|
|
| |
|
| Tension Column
Type |
- Strain Gauge Wheat-stone Bridge Principle
- From 500 Kg. to 100 Tonne in various Ranges
&
Models
- Integral Design
- Safe Over Load: 125% of Rated
Capacity
- Maximum Over Load : 150%
of Rated Capacity
- Fatigue Rating : 10 E6 Full
Cycles
- Excitation Maximum: 10 VDC
- Sensitivity: 1 mV/V [Nominal]
- Temperature Range: +10 Deg.
C. to +50 Deg. C.
|
|
| |
|
| Universal
‘S’ Type |
- Strain Gauge Wheat-stone Bridge Principle
- From 5 Kg. to 20 Tonne in various Ranges &
Models with Hooks for Tension Application
- Safe Over Load: 125% of Rated
Capacity
- Maximum Over Load : 150%
of Rated Capacity
- Fatigue Rating : 10 E6 Full
Cycles
- Excitation Maximum: 10 VDC
- Sensitivity: 2 mV/V [Nominal]
- Temperature Range: +10 Deg.
C. to +50 Deg. C.
|
|
| |
|
| Pan Cake /
Fatigue Resistant Type |
- Strain Gauge Wheat-stone Bridge Principle
- From 200 Kg. to 50 Tonne in various Ranges
& Models
- Safe Over Load: 125% of Rated
Capacity
- Maximum Over Load : 150%
of Rated Capacity
- Fatigue Rating : 10 E6 Full
Cycles
- Excitation Maximum: 10 VDC
- Sensitivity: 2 mV/V [Nominal]
- Temperature Range: +10 Deg.
C. to +50 Deg. C.
|
|
| |
|
| Button Type |
- Strain Gauge Wheat-stone Bridge Principle
- From 100 Kg. to 10 Tonne in various Ranges
& Models
- Safe Over Load: 125% of Rated Capacity
- Maximum Over Load : 150%
of Rated Capacity
- Fatigue Rating : 10 E6 Full
Cycles
- Excitation Maximum: 10 VDC
- Sensitivity: 1 mV/V [Nominal]
- Temperature Range: +10 Deg.
C. to +50 Deg. C.
|
|
| |
|
| Ball Seating
Type |
- Strain Gauge Wheat-stone Bridge Principle
- From 100 Kg. to 50 Tonne in various Ranges
& Models
- Safe Over Load: 125% of Rated
Capacity
- Maximum Over Load : 150%
of Rated Capacity
- Fatigue Rating : 10 E6 Full
Cycles
- Excitation Maximum: 10 VDC
- Sensitivity: 1 mV/V [Nominal]
- Temperature Range: +10 Deg.
C. to +50 Deg. C.
|
|
| |
|
| Beam Type |
- Strain Gauge Wheat-stone Bridge Principle
- From 100 Kg. to 10 Tonne in various Ranges
& Models
- Safe Over Load: 125% of Rated
Capacity
- Maximum Over Load : 150%
of Rated Capacity
- Fatigue Rating : 10 E6 Full
Cycles
- Excitation Maximum: 10 VDC
- Sensitivity: 1 mV/V [Nominal]
- Temperature Range: +10 Deg.
C. to +50 Deg. C.
|
|
| |
|
| Flange Compression
Type |
- Strain Gauge Wheat-stone Bridge Principle
- From 500 Kg. to 500 Tonne in various Ranges
& Models
- Safe Over Load: 125% of Rated
Capacity
- Maximum Over Load : 150%
of Rated Capacity
- Fatigue Rating : 10 E6 Full
Cycles
- Excitation Maximum: 10 VDC
- Sensitivity: 1 mV/V [Nominal]
- Temperature Range: +10 Deg.
C. to +50 Deg. C.
|
|
| |
|
| .Low Capacity
Universal Type |
- Strain Gauge Wheat-stone Bridge Principle
- From 1 Kg. to 200 Kg. in various Ranges &
Models
- Safe Over Load: 125% of Rated
Capacity
- Maximum Over Load : 150%
of Rated Capacity
- Fatigue Rating : 10 E6 Full
Cycles
- Excitation Maximum: 10 VDC
- Sensitivity: 1 mV/V [Nominal]
- Temperature Range: +10 Deg.
C. to +50 Deg. C.
|
|
| |
|
| Load Indicator |
- 3 ½ OR 4 ½ digit LED / LCD Displays
- Single Channel OR Multi-Channel
- Various Options:
- Set Points & Outputs
- Voltage & Current Outputs
- Peak hold / Reset Facility
- RS 232 / Centronics Outputs
- Remote Inputs etc.
- Calibration in Required Units
- In Various Cabinet Sizes
- +10 Deg.C. to +45 Deg.C.
- 230 Volts AC, 50 Hz., Single Phase Operated
|
|
| |
|
| Signal Conditioner |
- Single Channel OR Multi-Channel
- Voltage OR Current Outputs
- In Various Cabinet Sizes
- +10 Deg.C. to +45 Deg.C.
- 230 Volts AC, 50 Hz., Single Phase Operated
|
|
| |