Products | Application Field | Collaborators | Careers | Map | Downloads | Useful Info
Air Leak Testers & Peripheral Equipment
Air Leak Testing Systems
Load Cells / Indicators
Displacement Sensors / Indicators
Pressure Sensors / Indicators
Torque Sensors / Indicators
Vibration Sensor / Indicator
Lathe Tool Sensor / Indicator
Drill Tool Sensor / Indicator
Mill Tool Sensor / Indicator
Strain Indicators
Strain Calibrators
Vibration Exciters / Power Oscillators
Speed / Event Count Indicators
Photo / Laser / Ultrasonic & Vision Sensors
Data Loggers
Spring Testing Machines
Torque Calibration Equipment
Load Calibration Equipment
Educational Lab Set-ups
PC based Measurement Instrumentation & Software
SYSCON presents wide range of Air Leak Testing Models, expertise and technology to suit every application from Fukuda Company Limited, Japan -–World leaders in Air Leak Testing & Flow Measurement Systems.

Fukuda was established in 1962 as a developer and manufacturer of medical and industrial sensors. Additionally, Fukuda continues to be a world leader in producing Air Leak Testers with various technologies.

There are various kinds of pressure in our daily lives pressure exists in Cars, Air-conditioners and Mobile Phones. It exists in production factories, civil engineering and construction sites, environmental and pollution assessment, medical examinations and space exploration by space shutters.

Fukuda controls these invisible pressures and allows a peace of mind and safety.

Fukuda supports our daily lives in unsuspecting places; several components of our daily life must be free of leakage or be airtight. Examples of these include, gas appliances, water pipes, car engines, brakes, refreshment cans, syringes, medicine bottles, air conditioner, mobile phones and electronic components.

Fukuda has many years continued to supply industrial measuring equipment such pressure testers, leak testers, and flow meters to various industry such as automotive, electronics, household appliances, medical equipment and precision apparatus.

Fukuda’s Measuring Equipment support, a safe set of standards for manufacturers and users by avoiding risks caused by a lack of airtight environments, dangerous events or operational errors.

Fukuda is currently focussing on differential pressure and accepted the challenge of collecting diverse and microscopic information existing on a molecular scale.

Fukuda’s continuos product development technology caters to the various needs of the measurement.

Masterless Leak Tester – FL 600 Series
  • Shortened Testing Time – Advanced Data Management allows reduction of Testing Time
  • Detection Accuracy – Possible to conduct high S/N Testing, eliminates temperature influences and test various work parts
  • Masterless – Eliminates Master Management Processes
  • Improving outside factors – Problems involved with testing systems are assigned a numerical valve consequency; problems are solved with effective counter measures
  • Corresponds to Multiple work parts – Flexibility allows multiple work parts adaptability
  • Extensive Maintenance Functions – Auigomatic self check functions for internal varies and various sensors. Flow Master and Calibrator allow volume testing and sensitivity verification
  • Model : V, UL, L, M, H
  • Pressure Range :
    • V for Vacuum type: -5.0 ~ -90.0 kPa
    • UL, L, M, H for Pressure type: 5.0 - 990 kPa
 
Multi-purpose Leak Tester FL-601 Series

Revolutionary differential pressure type Masterless Air Leak Tester takes our FL-600 Series one step further into future. This space saving instrument will lead to gradual reduction in leading costs, and the detection time has become even shorter.

  • Model : V, UL, L, M, H, H1
  • Pressure Range :
    • V for Vacuum type: -5.0 ~ -90.0 kPa
    • UL, L, M, H, H1 for Pressure type: 5kPa ~ 2.00 MPa
 
Corresponds to Work Volume Leak Testers
FL-2600, 2700, 3600, 3700, 3800 Series
  • FL-3600/3700 Series with turbo function loaded
    FL-2600/2700 Series without turbo function loaded
  • Turbo Function Loaded - Without Master work piece rapid stabilizing function
  • 10 Channel Group Setting – 10 kinds of different conditions can be set
  • Sensor Protect Circuit – Built-in circuitry to prevent moisture and oil from the work entering sensor
  • Data Management – Powerful line of Leak Tester designed to the product volume and to perform high accurate leak testing
  • Model : V, UL, L, M, H, H1, H2
  • Pressure Range :
    • Vacuum type : -7.0 ~ -90.0 kPa
    • Pressure type: 5 kPa ~ 3.5 MPa
  • Work Volume : 1ml to 50 Litres
 
Compact Air Leak Testers
FL-273, 283, 284, 294 Series
  • Compact Body, Collected substantial functions, High durability & Easy Operation
  • Model : V, L, M, H
  • Pressure Range
    • : V for Vacuum type : -20 ~ -90 kPa
    • L,M,H for Pressure type: 10 kPa ~ 990 kPa
 
Compact Air Leak Testers
FL-286, 296 Series
  • Compact Body, Collected substantial functions, High durability & Easy Operation
  • Model : UL, L, H
  • Model and Pressure Range:
  • UL type : -10 ~ 10 kPa
  • L type : -100 ~200 kPa
  • H type : -100 ~990 kPa
 
Separate Leak Tester - LPU Series

The LPU Series our separate Air Leak Tester Measurement Units intended to be embedded in automated equipment. Complete Air Leak Tester can be created by pairing a separate Leak Tester with an option display unit (MI-170, DG-960)

  • Model & Pressure Ranges
  • V for Vacuum: -6.0 ~ -100 kPa
  • L for Low Pressure: 5.0 ~ 200 kPa
  • H for High Pressure : 100 ~ 900 kPa
 
Multi Indicator – MI-170 Series
  • Mounting Size: DIN 96
  • Internal Sensor Type
    [External Sensor is also available]
  • Number of Display Digits : 4
  • High / Low 4 Point Limit Setting
  • Pressure Ranges: 21 types
  • Auto-zero Function
  • Hold Function
  • Analog Output
  • BCD Output
  • RS-232C I/O
  • 8 Group Switch Function
  • Various Functions
  • Power Source: AC100V
 
Digital Manometer – DG-960 Series
  • Mounting Size: DIN 96
  • Internal Sensor Type
    [External Sensor is also available]
  • Number of Display Digits : 3 ½
  • High / Low Limit Setting
  • Pressure Ranges: 21 types
  • Auto-zero Function
  • Hold Function
  • Analog Output
  • BCD Output
  • Power Source: AC100V
 
Digital Manometer – DG-72 Series
  • Mounting Size: DIN 96
  • Internal Sensor Type
    [External Sensor is also available]
  • Number of Display Digits : 4
  • High / Low 4 Point Limit Setting
  • Pressure Ranges: 21 types
  • Auto-zero Function
  • Hold Function
  • Analog Output
  • BCD Output
  • RS-232C I/O
  • 8 Group Switch Function
  • Various Functions
  • Power Source: AC100V
 
Electric Pneumatic Regulators APU Series

The APU Regulator, capable of electrically controlling Pneumatic pressure, employs Fukuda’s originally developed highly accurate, quick responding and stable circuit structures. Feedback from external sensors instantly regulates pressure flow. Various models available to control small to large flow volumes.

Feedback from external sensors instantly regulates pressure flow.
Capable of controlling pressure flow rate through voltage or electric current in succession
Response time of 1 sec ~ 2 sec
Various models available to control small to large flow volumes
Various models available for a variety of pressure applications

  • Applications:

    Load Control for Precision Grinding
    Pressure Control for fluid Measurements
    Various Types of Control for Torque or Gripping
    Various Types of Control for Discharge Pressures and Discharge Flows
    Overall Verification of Pressure Sensors and Pressure Switches, etc.
    Pressure Control for Casting, Molding, etc.
  • Accuracy : ±0.1%
  • Pressure Range: ±2 kPa ~ ±500 kPa and +900 kPa
 
Flow Tester FM-1060 Series

FM-1060 Series is a Flow Tester which houses a thermal flowmeter. It reduces measurement time by using scan function

  • Model: V, UL, L, M
  • Pressure Range:
    • V for Vacuum type : -5 ~ 50kPa
    • UL, L, M for Pressure type: 100 ~ 500 kPa
  • Flow Rate:
    • 500M: 50 ~ 500 ml
    • 2L: 0.2 ~ 2 l / min.
    • 5L: 0.5 ~ 5 l / min.
    • 20L: 2 ~ 20 l / min.
    • 50L: 5 ~ 50 l / min.
 
Laminar FLF Series
  • Speed Response Characteristics
  • Small Pressure Loss
  • Tough for Impurity
  • Applied Pressure Range –20 ~ 100 kPa
  • Model: 20CM ~ 20 LM
  • Flow Range: 2 ~ 20 (ml/min.) to 2 ~ 20 (l/min.)
 
Flow Unit FU Series
  • Integral Structure makes it inexpensive and easy to operate flow measurement
  • Display separate unit makes it easy to integrate into equipment enable to employ pipeline as minimum structure
  • Applied Pressure Range: -20 ~ 100 kPa
  • Power Source: DC ± 15 V within 0.05 A
  • Model: 10M ~ 5L
  • Test Range: 1 ~ 10 (ml/min.) to 0.5 ~ 5 (l/min.)
 
Gauge Pressure Sensor SX-34 Series
  • Rev Over Pressure: 1.5 X of F.S.
  • Media Compatibility: Air, Non-corrosive Gas
  • Fitting: Rc 1/8 (setting range below 1 Mpa: R ¼ )
  • Accuracy: ±1% F.S.
  • Power Source : ±15 V
  • Range: 20 kPa ~ 20 Mpa and –100 kPa
  • Output: 0 ~ 1V / 0 ~ -1V (Additional Output options available)
 
Gauge Pressure Sensor PI-100C Series
  • Over Pressure: 2 X of F.S.
  • Media Wetted Parts: SUS304 Stainless Steel
  • Media Compatibility: Air, Non-corrosive Gas, Liquids
  • Accuracy: ±0.3% of F.S. (including hysterisis) or less
  • Thermal Effects:
  • Null: ±0.03% of F.S. / Deg.C.
  • Span: ±0.03% of F.S. / Deg.C.
  • Response Time: 10ms or Less for Step Input
  • Operating Temperature Limit: 0 to 40 Degrees C.
  • Power Source : ±15V, 100mA
  • Range : 10 kPa ~ 20 Mpa and –100 kPa
  • Output: 0 ~ 1V / 0 ~ -1V (Additional output options available)
 
Differential Pressure Sensor SX-100C,SX-100D Series

Over Pressure: 2 X of F.S.
Media Wetted Parts: BSB Brass Steel
Line Pressure Tolerance:
(Null when Charging the Same Pressure of ± Port)
within 0.5% F.S. (Applying MAX Line Pressure)
Media Compatibility: Air, Non-Corrosive Gas

  • Accuracy:
    Within ±0.15% of F.S. or Less (SX-100D)
    Within ±0.3% of F.S. or Less (SX-100C)
  • Thermal Effects:
    Null: ±0.02% of F.S. / Deg. C. or Less
    Span: ±0.02% of F.S. / Deg. C.
  • Power Source: ±15V, 100mA
  • Range: ±1 kPa ~ 1Mpa and –100 kPa
  • Output: ±1V (Additional output options available)
 
Differential Pressure Sensor VR-55PT-TCP Series
  • Over Pressure: 1Mpa
  • Media Wetted Parts: SUS410 Stainless Steel
  • Line Pressure Tolerance:
    (Null when Charging the Same Pressure of ± port) Within 0.5% of F.S. (Applying MAX line pressure)
  • Media Compatibility: Air, Non-corrosive gas
  • Accuracy: Within ±0.5% of F.S. or Less
  • Thermal Effects:
    • Null: ±0.05% of F.S. / Deg.C. or Less
    • Span: ±0.05% of F.S. / Deg.C.
  • Power Source: ± 15V, 100 mA
  • Range: ±1kPa ~ ±10 kPa
  • Output: ±1V (Additional Output Options are available)
 
Flow Master FFM-100 Series

Detachable – The attachment and detachment to a main body can be performed, without removing measurement piping, by equipping the measurement circuit with coupling before hand

  • Routine – During the routine measurement, a plug is attached in coupling and the measurement course is changed in to a sealing state
  • Measurement – In case it measures, measurement becomes possible by substituting a plug into the main body
  • Pressure Range:
    • Pressure type: 10 kPa ~ 800 kPa
    • Vacuum type : 10 kPa ~ -80 kPa
    • Flow Rate : 0.1 ml/min. ~ 10.0 ml/min ±5%
    • Connection Caliber Coupling: R- ¼ (coupling)
 
Pressurization & Exhaust Bypass Unit

By using a pressurizations & exhaust by-pass unit you can reduce the test time of a large volume work and obtain stable measurement results

  • Model: EBU CBU
  • Power Supply Voltage: DC 24 V
  • Consumption Current: 0.1 A
 
Exhaust Bypass Unit

Allows pressurized air to exit from the work during the exhaust phase without passing through to the tester

  • Model: FE-20
  • Power Supply Voltage: AC-100V ±10%
  • Power Consumption: 1.8W
 
Calibrator

This is used in conjunction with a differential pressure Air Leak Tester, it can be used to check the sensitivity of an air leak tester or measure the volume of work by examining the developed differential pressure.

 

 

ˆ Top
© 2007 Syscon Instruments Pvt. Ltd.
Powered by Business Online, Bangalore